Part 5 of 8 – Cable Sizing and System Protection
Attempts allowed: 4
Grading method: Highest grade
Quiz Summary
0 of 24 Questions completed
Questions:
Information
You have already completed the quiz before. Hence you can not start it again.
Quiz is loading…
You must sign in or sign up to start the quiz.
You must first complete the following:
Results
Results
0 of 24 Questions answered correctly
Your time:
Time has elapsed
You have reached 0 of 0 point(s), (0)
Earned Point(s): 0 of 0, (0)
0 Essay(s) Pending (Possible Point(s): 0)
Categories
- Not categorized 0%
- Review
- Answered
- Correct
- Incorrect
-
Question 1 of 24
1. Question
Question 1
Size the DC Cables for the PV Array based on voltage drop and CCC. Select the MPPT with the greatest number of modules and the furthest string from the inverter. Use the simple resistivity method for sizing of the cables and voltage drop calculations. For the CCC consideration assume the following: unenclosed, exposed to sun, two single core cables. Refer to balance of system online book for a refresher on cable sizing.CorrectIncorrect -
Question 2 of 24
2. Question
Question 2
-
i) Length of the longest cable run for the DC side(one way from the furthest panel to the inverter): m (closest metre)
ii) Number of modules in the string:
(This is what you selected in the configuration section. Please select the MPPT with the largest number of modules)
iii) What is the voltage flowing through your PV string cable (Vcable): V
iv) Minimum required size of the DC string cable according to CCC considerations: mm2
v) State the selected STRING cable size. mm2
vi) What is the actual voltage drop based on the selected string cable size you have chosen? V
vii) What is the percent voltage drop based on the voltage at the maximum power point? %
CorrectIncorrect -
-
Question 3 of 24
3. Question
Question 3
b) Sizing of PV array cables
-
i) How many strings will you parallel to a single MPPT in your design (select the MPPT with the greatest number of strings)?
ii) Minimum ARRAY cable size: mm2
CorrectIncorrect -
-
Question 4 of 24
4. Question
c) Selection of PV overcurrent protection devices
-
Determine whether the following PV system devices are needed and size them.
Is string overcurrent protection required for this installation? (Y/N)
If string OCPD is required what would be the current trip limits of the overcurrent protection?
< String overcurrent protection fuse ≤:
CorrectIncorrect -
-
Question 5 of 24
5. Question
Question 5
Rooftop PV Array Disconnection Method
CorrectIncorrect -
Question 6 of 24
6. Question
Question 6
If a protection device is not required, set the size to 0 A.
-
Rooftop DC Isolator: A
DC Isolator next to inverter: A
CorrectIncorrect -
-
Question 7 of 24
7. Question
Question 7
d) Minimum allowable AC cable size based on voltage dropSelect the cable type that will be used for the AC cables
CorrectIncorrect -
Question 8 of 24
8. Question
Question 8
i) What method must be used for the calculations of the AC cable sizing selection
CorrectIncorrect -
Question 9 of 24
9. Question
Question 9
Fill the blanks
-
ii) What is the voltage flowing through your AC cable cable (Vcable): V
Assume a 1% maximum permissible voltage rise from the inverter to MSB (specified by the NSW service and installation rules) and a conservative cable run of 3m.
iii) What is the maximum permissible voltage rise on the AC cable? V
iv) What is the maximum single phase millivolt rise per amp-metre route length VC of the AC cable? mV/Am
v) What is the minimum area of the AC cable based on the minimum Vc calculated above assuming a multicore circular copper conductor was used? mm2
CorrectIncorrect -
-
Question 10 of 24
10. Question
Question 10
Please include your working out and/or reasoning in this area.
(Assume your selected cable at max power factor)
-
This response will be reviewed and graded after submission.
Grading can be reviewed and adjusted.Grading can be reviewed and adjusted. -
-
Question 11 of 24
11. Question
Question 11
e) Minimum allowable AC cable size based on current carrying capacity (CCC)
For the CCC consideration assume the following: enclosed, wiring enclosure in air, two-core cables.-
i) What is the minimum required CCC of your AC cable: A
ii) Minimum required size of the AC cable based only on CCC considerations and standards. For CCC use the nominal current. Do not oversize this answer. mm2
CorrectIncorrect -
-
Question 12 of 24
12. Question
Question 12
Please include your working out and/or reasoning in this area.
-
This response will be reviewed and graded after submission.
Grading can be reviewed and adjusted.Grading can be reviewed and adjusted. -
-
Question 13 of 24
13. Question
Question 13
f) Actual AC cable size used in this design
-
i) Based on the above voltage rise and CCC sizing constraints, as well as the standards and overcurrent protection state the cable size you will use in your design for the AC cable. mm2
ii) What is the actual voltage rise calculated based on the selected cable size you have chosen? (2 decimal places) V
iii) What is the percent voltage rise? (2 decimal places) %
CorrectIncorrect -
-
Question 14 of 24
14. Question
Question 14
Please include your working out and/or reasoning in this area.
-
This response will be reviewed and graded after submission.
Grading can be reviewed and adjusted.Grading can be reviewed and adjusted. -
-
Question 15 of 24
15. Question
Question 15
In this question we will size the battery protection device and the cable between the battery and the inverter. The cable will be sized based on the continuous rating of the protection device to protect the cable.
- Use the simple resistivity method for sizing of the cables and voltage drop calculations.
- For the CCC consideration assume the following: enclosed, wiring enclosure in air, single core cable.
- Refer to balance of system online book for a refresher on cable sizing.
CorrectIncorrect -
Question 16 of 24
16. Question
Question 16
Fill the blanks
-
ii) State the rating of the in-built battery protection device. A
iii) State the battery maximum continuous output current: A
iv) State the battery nominal voltage, this will be the minimum rating of the battery protection device. V
v) State the fault current rating of the battery protection device. kA
CorrectIncorrect -
-
Question 17 of 24
17. Question
Question 17
h) Sizing of the cable between the battery and the inverter
Select cable type:
CorrectIncorrect -
Question 18 of 24
18. Question
Question 18
-
i) Length of the cable run: m
ii) Minimum required size of the cable according to CCC and overcurrent protection considerations: mm2
iii) Exact minimum required size of the cable due to fault current (answer to two decimal places): mm2
Assume the duration of the short circuit is t = 0.1s before the circuit breaker trips (a significant buffer). Refer to fault current sizing in the balance of system online book. Please provide the exact value to 2 decimal places, do NOT round up to next largest cable size.
CorrectIncorrect -
-
Question 19 of 24
19. Question
Question 19
-
This response will be reviewed and graded after submission.
Grading can be reviewed and adjusted.Grading can be reviewed and adjusted. -
-
Question 20 of 24
20. Question
Question 20
-
iv) State the SELECTED cable size: mm2
v) Calculate the voltage drop for the selected cable size: V
vi) Calculate the percent voltage drop: %
CorrectIncorrect -
-
Question 21 of 24
21. Question
Question 21
Please include your working out and/or reasoning in this area.
-
This response will be reviewed and graded after submission.
Grading can be reviewed and adjusted.Grading can be reviewed and adjusted. -
-
Question 22 of 24
22. Question
i) Sizing of the battery earth cable
Hint: Ensure your earth cable is sufficient for your DVC level.
-
State a suitable earth conductor cable size:
CorrectIncorrect -
-
Question 23 of 24
23. Question
Question 23
j) Selection of PPE for arc flash protection
Note: This may not necessarily need to be calculated for pre-assembled batteries, but still recommended. Assume the system is not installed in a dedicated battery room.
-
i) Calculate the arc flash energy for the battery: cal/cm2
Hint: For the arc flash boundary distance use the “nominal” working distance. Refer to Preliminary System Design Chapter -> site-specific Hazards and Risks -> Energy Hazards.
ii) Based on the arc flash energy (cal/cm2) what PPE level is required?
[data-xtranslate-tooltip]:hover [data-xtranslate-tooltip]::after[data-xtranslate-tooltip][data-xtranslate-tooltip]:hover[data-xtranslate-tooltip]:hover::after[data-xtranslate-tooltip]::after
CorrectIncorrect -
-
Question 24 of 24
24. Question
Question 24
Please include your working out and/or reasoning in this area.
-
This response will be reviewed and graded after submission.
Grading can be reviewed and adjusted.Grading can be reviewed and adjusted. -