Part 4 of 8 – Sizing and selection of the PV Array
Attempts allowed: 4
Grading method: Highest grade
Quiz Summary
0 of 5 Questions completed
Questions:
Information
You have already completed the quiz before. Hence you can not start it again.
Quiz is loading…
You must sign in or sign up to start the quiz.
You must first complete the following:
Results
Results
0 of 5 Questions answered correctly
Your time:
Time has elapsed
You have reached 0 of 0 point(s), (0)
Earned Point(s): 0 of 0, (0)
0 Essay(s) Pending (Possible Point(s): 0)
Categories
- Not categorized 0%
- Review
- Answered
- Correct
- Incorrect
-
Question 1 of 5
1. Question
In this section you will size and match the PV array to the Fronius Primo Gen24 Plus inverter we have selected in the previous part. Refer to the design task instructions for site-specific information and temperatures. For a refresher of matching array and inverter refer to: Equipment Sizing and Selection => “Sizing PV Array” and “Matching the PV Array and Inverter Example”.
-
a) Calculations for the maximum number of modules in the system:
i) Maximum DC power permitted based on inverter datasheet: kW
ii) Maximum total number of modules that can be connected to the inverter based on max power requirements (rounded):
CorrectIncorrect -
-
Question 2 of 5
2. Question
Please include your working out in this area.
-
This response will be reviewed and graded after submission.
Grading can be reviewed and adjusted.Grading can be reviewed and adjusted. -
-
Question 3 of 5
3. Question
Qestion 2
Include your working here.
-
This response will be reviewed and graded after submission.
Grading can be reviewed and adjusted.Grading can be reviewed and adjusted. -
-
Question 4 of 5
4. Question
Question 3
b) Calculations for sizing the minimum number of PV modules in a string, (perform all calculations to 2 decimal places):
CorrectIncorrect -
Question 5 of 5
5. Question
b) Calculations for sizing the minimum number of PV modules in a string, (perform all calculations to 2 decimal places):
-
Inputs:
ii) What is the value of your selected voltage? V
iii) What is the temperature coefficient in %/°C? %/°C
iv) What is the module cell temperature? °C
v) What is the STC temperature value? °C
vi) What is the value of the inverter voltage you will use for this calculation? V
vii) What is the multiplying factor you will use for safety on the inverter voltage? (please input a decimal, not percent)Calculations:
viii) What is the difference in voltage due to the temperature adjustment? 6.88 V
CorrectIncorrect -