Part 2 of 7 – Sizing and selection of the BESS equipment
Attempts allowed: 4
Grading method: Highest grade
Quiz Summary
0 of 6 Questions completed
Questions:
Information
You have already completed the quiz before. Hence you can not start it again.
Quiz is loading…
You must sign in or sign up to start the quiz.
You must first complete the following:
Results
Results
0 of 6 Questions answered correctly
Your time:
Time has elapsed
You have reached 0 of 0 point(s), (0)
Earned Point(s): 0 of 0, (0)
0 Essay(s) Pending (Possible Point(s): 0)
Categories
- Not categorized 0%
- Review
- Answered
- Correct
- Incorrect
-
Question 1 of 6
1. Question
Question 1
a) Selection of the most suitable battery system layout
The battery system must use components from the provided component list in the design task instructions and the component specification sheets folder. Consider the cost and ease of installation.
CorrectIncorrect -
Question 2 of 6
2. Question
Question 2
In this question you will be selecting and sizing the battery based on the loads and demands. Note: Selecting and sizing the battery is an iterative process. The process is as follows:
- Select a battery from the provided list in the project brief.
- Calculate the loads and maximum demand the grid connected battery needs to supply.
- Ensure the battery you selected is suitable for your loads and maximum demand you just calculated.
- If it is not suitable you will either need to select a different battery or simply increase the number of batteries.
- In the next question you will state the final BESS and configuration.
a) Determine the minimum usable battery capacity to supply the loads during the 5 – 11pm period. Assume the cable efficiency from the battery to the loads is 97%. Answer to two decimal places and count a minimum usable battery capacity in Wh
Hint: Ensure you include the relevant efficiencies in your calculation; BESS efficiency, cable efficiency and battery capacity temperature derating. Refer to sizing and selecting battery storage book.
-
This response will be awarded full points automatically, but it can be reviewed and adjusted after submission.
Grading can be reviewed and adjusted.Grading can be reviewed and adjusted. -
Question 3 of 6
3. Question
Question 3
b) Determine the maximum demand required to supply the loads during the 5-11pm period. Answer to two decimal places and count maximum demand battery must supply in ‘VA’
-
This response will be awarded full points automatically, but it can be reviewed and adjusted after submission.
Grading can be reviewed and adjusted.Grading can be reviewed and adjusted. -
-
Question 4 of 6
4. Question
Question 4
c) Selection of BESS equipment and configurationChoose BESS Brand Model & Configuration
CorrectIncorrect -
Question 5 of 6
5. Question
Question 5
Can your selected battery provide (a) the capacity, and (b) the maximum demand that you have calculated? If not, will increasing the number of batteries work? Will selecting another battery model work better? State your final BESS configuration in this question.-
c) Selection of BESS equipment and configuration
State the selected BESS with their size and configuration. Refer to the BESS datasheet and manufacturer’s installation manual. Answer with two decimal points.
Required minimum capacity of BESS (previous question) kWh Total Usable Capacity of BESS kWh Required maximum demand of BESS (previous question) kVA Total Rated power of BESS (real) kW Total Rated maximum demand of BESS kVA UN number
CorrectIncorrect -
-
Question 6 of 6
6. Question
Question 6
List your reasons for selecting this battery
-
This response will be reviewed and graded after submission.
Grading can be reviewed and adjusted.Grading can be reviewed and adjusted. -